BHLCF - 531 CURING MEMBRANE REMOVER
- MSDS: BHLCF
- Manufacturer: TENNANT COMPANY
- Product Name: 531 CURING MEMBRANE REMOVER
- National Stock Number: 6850-00F009554
Product Identification
Product ID:531 CURING MEMBRANE REMOVER
MSDS Date:11/01/1985
FSC:6850
NIIN:00F009554
MSDS Number: BHLCF
Responsible Party
Emergency Phone: (612) 540-1381
Info Phone: (612) 540-1381
Cage: D0218
Contractor
Telephone: 612-540-1556/800-553-8033
Cage: D0218
Ingredients
2-BUTOXYETHANOL
CAS: 111-76-2
RTECS: KJ8575000
Fraction By Weight: 1-8%
OSHA PEL S, 50 PPM
ACGIH TLV: S, 25 PPM; 9293
NONIONIC SURFACTANTS
Fraction By Weight: 1-5%
AROMATIC HYDROCARBON 150
Fraction By Weight: 80-90%
METHYLENE CHLORIDE (SARA III)
CAS: 75-09-2
RTECS: PA8050000
Fraction By Weight: 1-8%
OSHA PEL 500 PPM/C,1000; Z2
ACGIH TLV: 50 PPM, A2; 9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN/EYE: IRRITATION & INJURY.
INGESTION: BURNING SENSATION, VOMITING, DIARRHEA, DROWSINESS &
TISSUE DAMAGE. ASPIRATION INTO LUNGS CAN CAUSE CHEMICAL PNEUMONITIS
WHICH CAN BE FATAL. INHALATION: RESPIR ATORY TRACT
IRRITATION/NERVOUS SYSTEM DEPRESSION, HEADACHE, DIZZINESS,
STAGGERING GAIT, CONFUSION & UNCONSCIOUSNESS.
Explanation of Carcinogenicity:METHYLENE CHLORIDE IS CONSIDERED TO BE
AN A2 CARCINOGEN BY ACGIH.
Effects of Overexposure:SKIN/EYE: IRRITATION & INJURY. INGESTION:
BURNING SENSATION, VOMITING, DIARRHEA, DROWSINESS & TISSUE DAMAGE.
ASPIRATION INTO LUNGS CAN CAUSE CHEMICAL PNEUMONITIS WHICH CAN BE
FATAL. INHALATION: RESPIR ATORY TRACT IRRITATION/NERVOUS SYSTEM
DEPRESSION, HEADACHE, DIZZINESS, STAGGERING GAIT, CONFUSION &
UNCONSCIOUSNESS.
First Aid
First Aid:SKIN: WASH THOROUGHLY W/SOAP & WATER. EYE: FLUSH W/WATER FOR
15 MINUTES. CALL PHYSICIAN. INGESTION: CALL PHYSICIAN. DON'T
ATTEMPT TO INDUCE VOMITING. INHALATION: REMOVE TO FRESH AIR.
RESTORE BREATHING IF REQUIRED. IF BREATHING DIFFICULTY PERSISTS,
CONSULT PHYSICIAN.
Fire Fighting
Flash Point Method:SCC
Flash Point:120F
Lower Limits:0.9%
Upper Limits:6.0%
Extinguishing Media:CO2, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WATER MAY BE USED TO COOL CLOSED CONTAINERS TO
PREVENT PRESSURE BUILDUP/POSSIBLE AUTO IGNITION WHEN EXPOSED TO
EXTREME HEAT. FOG NOZZLES PREFERRED. USE SCBA.
Unusual Fire/Explosion Hazard:KEEP CONTAINERS TIGHTLY CLOSED. ISOLATE
FROM HEAT, SPARKS & OPEN FLAME. CLOSED CONTAINERS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. DON'T APPLY TO HOT SURFACES.
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION (FLAMES, HOT
SURFACES & SPARKS). AVOID BREATHING VAPORS. VENTILATE AREA. REMOVE
W/INERT ABSORBENT/SCRUB W/SOAP & WATER.
Handling
Handling and Storage Precautions:STORE IN COOL, DRY PLACE. STORE LARGE
QUANTITIES IN BUILDINGS DESIGNED & PROTECTED FOR STORAGE OF NFPA
CLASS II COMBUSTIBLE LIQUIDS.
Other Precautions:DON'T TAKE INTERNALLY. AVOID PROLONGED CONTACT
W/SKIN. CONTAMINATED CLOTHING SHOULD BE REMOVED IMMEDIATELY. AVOID
FREE FALL OF LIQUID IN EXCESS OF A FEW INCHES.
Exposure Controls
Respiratory Protection:WEAR A CHEMICAL RESPIRATOR APPROVED FOR ORGANIC
VAPORS (NIOSH TC 23C OR EQUIVALENT) DURING THE APPLICATION & UNTIL
WORK AREA HAS BEEN EXHAUSTED OF ALL VAPORS.
Ventilation:PROVIDE SUFFICIENT LOCAL EXHAUST VENTILATION TO KEEP
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:SAFETY SHOWER & EYEWASH FACILITY
Work Hygienic Practices:CONTAMINATED CLOTHING SHOULD BE REMOVED
IMMEDIATELY.
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:104F
Vapor Density:>AIR
Evaporation Rate & Reference:SLOWER THAN N-BU AC
Solubility in Water:EMULSIFIES
Appearance and Odor:CLEAR/HEAVY AROMATIC LIQUID
Percent Volatiles by Volume:96.4%
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:HEAT, SPARKS, & OPEN FLAME
Hazardous Decomposition Products:CO2, CO, & SMALL AMOUNTS OF HYDROGEN
CHLORIDE & PHOSGENE WHEN HEATED TO DECOMPOSITION.
Disposal
Waste Disposal Methods:INCINERATE IN FURNACE OR BURY IN LANDFILL IN
ACCORDANCE W/FEDERAL, STATE & LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.